Input, 4 input – Datalogic Scanning MATRIX 1000 User Manual

Page 29

Advertising
background image

INSTALLATION

19

2

2.3.4 Input


An opto-coupled and polarity insensitive input is available on the 25-pin connector.
The pinout is the following:

Pin Name

Function

18

EXT_TRIG A

External trigger (polarity insensitive)

19

EXT_TRIG B

External trigger (polarity insensitive)


When current flows through the EXT_TRIG input, the yellow LED (Figure A, 6) is on.

The External Trigger can be used in One Shot Mode or in Phase Mode. Its main
functions are:

acquisition trigger in One Shot Mode

phase-ON/phase-OFF command in Phase Mode

match code storage command.


This input can be driven by either a PNP or NPN type command. The connections
are indicated in the following diagrams:

NOTE

Polarity insensitive input assure full functionality even if pins A and B
are exchanged.

USER INTERFACE

OUT

MATRIX

V

CC

A

Vext

B

GND

V

+

~

~

+

-

I

in

30 Vdc Max.

Figure 17 - Input PNP Command Using External Power

Advertising