INSTALLATION

21

2

An anti-disturbance filter (debouncing) is implemented on the input, and is software
programmable. The

input active state can be defined by the user as well. Refer to the

digital I/O folder in the VisiSet™ Help On Line for further details.


2.3.5 Outputs


One optocoupled general purpose output is available on the 25-pin connector. The
pinout is the following:

Pin Name

Function

16

OUT3+

Configurable digital output 3 - positive pin

17

OUT3-

Configurable digital output 3 - negative pin

It is typically used to signal the data collection result. It can also be used to control an
external lighting system

The idle state, the activation/deactivation events and the other configuration
parameters can be defined by the user. Refer to the Digital I/O folder in the VisiSet™
Help On Line for further details.


MATRIX

USER INTERFACE

Vext 30 Vdc max

+

-

I

Load

V

Out

Figure 21 - Open Collector Output Connection

The electrical features of the output are the following:

OUTPUT I

Load

V

Out

Open

0 mA

30 Vdc Max

Closed

10 mA

1.8 Vdc Max

P

D

= V

Out

×

I

oLoad

= 170 mW Max.