Digi-Star SW2600EID User Manual

Page 19

Advertising
background image

Operators Manual

D3718

19

Setting/
Display

Options
(

Bold

= Default)

Description

Auto Print

(

APRINT

)

ON/

OFF

Pressing keys will automatically print

weight values.

Print Format

(

PRTFMT

)

AUTO

See Page 34 for details.

Zero Out

Press & hold

Com 1 Delay

(

C1 DLY

)

OFF

,.10,.25,.50,.75,

1-5

Seconds printer delays before

advancing line.

Com 2 Delay

(

C2 DLY

)

OFF

,.10,.25,.50,.75,

1-5

Estimated

Weight

(

EST WGHT

)

0

,1,2,3,4,5,6,7,8,9 Enter weight on scale

Menu 3

Display Count

(

COUNT

)

.01,

.02

,.05,.1,.2,.5,1,

2,5,10,20, 50,100

Count set too small, readings

unstable and indicator not accurate

Auto-Range

(

ARANGE

)

ON/

OFF

Scale increases display count size

for weights over 300 again at 600

lbs/kgs.

Display Unit

(

LB-KG

)

LB

/KG

When changing weight unit

calibration adjusted so scale displays

accurately in new display unit

Capacity

(

CAP

)

4000

Enter maximum weight measurable

WM1

ADJUST

(

WMA 1-1

)

10

Increase number to smooth

weighing

WM1

ADJUST 2

(

WMA 1-2

)

0,1,2,3,

4

,5,6,7,8,9 0=OFF Use values less than WMA 1-

1 for quick weight response.

WM1

ADJUST 3

(

WMA 1-3

)

400

Enter weight to activate quick weight

response.

WM2

ADJUST 1

(

WMA 2-1

)

30

Increase number to smooth

weighing

Advertising