Scoreboard methods – Digi-Star SW2600EID User Manual

Page 38

Advertising
background image

SW2600EID

38

D3718

SCOREBOARD METHODS

Ten scoreboard methods available. Methods one thru six sends numeric

display data out RS232 port periodically while other methods send data

stream described below.

1. Transmit numeric display data once/second.

2. Transmit numeric display data two times/second.

3. Transmit numeric display data three times/second.

4. Transmit numeric display data at A-D conversion rate.

5. Transmit numeric display data at display rate.

6. Transmit numeric display data whenever a display weight changes.

7. Transmit status data string every second. Status data string includes

weight, rotation counter data, date and time.

8. Transmit status data every five seconds. Status data string includes

weight, rotation counter data, date and time.

9. Reserved.

10.Transmit EID data string every 2 seconds.

13.Transmit EIDVID data string every 2 seconds.

NOTES

: When using SCOREM = 1, 2, 3, 4, 5, 6 and 9 be sure to set

LSTORE = OFF, TAREAP = OFF and APRINT = OFF to avoid

corrupted data when transmitting scoreboard data and printing

scale data.

When using SCOREM = 7, 8 and 10, print data will not be

corrupted by scoreboard data.