Operators Manual

D3718

31

WEIGH METHODS

Select weigh method #4 for animal weighing. EID features require indicator

set in this mode. Use StockWeigh for stable loads, Lock-On Weigh

method. Other methods listed below.

NOTE:

Most of StockWeigh features require weigh method #4.

General Weigh Method #1

All purpose weigh method for stable loads.

Slow Weigh Method #2

Higher accuracy for weighing stable loads.

Fast Weigh Method #3

Determines new weight quickly when weighing stable loads.

Lock-on Weigh Method #4

Weighing active animals and displays stable accurate weight. Set to “OFF”

for weighing stable weights. Lock-On sensitivity can be adjusted using

“LOCKON” menu.

Once weight displayed, scale “Locks-On” to weight. Weight does not

change, even if motion never stops. Small ‘L’ appears on left side of the

display indicating weight “Locked-On.” Animal’s weight must be greater

than 2.5% of scales “capacity” weight before system “Lock-On.”

Break lock, 50% of displayed weight added or removed from scale.

“Locked-On” weight can be “rechecked” by pressing . This breaks “lock”

and scale recalculates weight.