SHORT FORM CALIBRATION

Short Form Setup & Calibration procedure allows changing “SETUP” and

“CAL” numbers of indicator.

Setup Number

The “SETUP” numbers affects some parameters that also appear in Long

Form Calibration. Following is a list of functions controlled by “SETUP”

number:

Weigh Method (W MTHD)

Display Units (LB-KG)

Display Counts (COUNT)

Gain

Scale Capacity

Calibration Number

The “CAL” number adjusted to make scale read proper weight for different

load cells and to make accuracy adjustments on scale system. If a

StockWeigh indicator provided with StockWeigh load cells as a package,

calibration number adjusted at factory for maximum accuracy. Systems

that are assembled from separate components are given “STANDARD

SETUP AND CALIBRATION NUMBERS” and are not factory calibrated.

These systems should be checked and adjusted if necessary using known

weights to insure accuracy. See “Calibrating the Scale for Maximum

Accuracy” below.

List of Standard Setup and Calibration numbers for StockWeigh 3300,

6600, 10000 and 14000 load cells shown below. If not using StockWeigh

load cells, contact Digi-Star Tech Support at 920-563-9700 for setup and

calibration information:

StockWeigh

Scale Type

Unit

Setup #

Calibration #

3300

Lbs

413004

776

6600

Lbs

413007

1560

10000

Lbs

454010

14000

14000

Lbs

443015

13828

3300

Kg

812002

352

6600

Kg

812003

708

10000

Kg

854010

6351

14000

Kg

843007

6272