12. PRODUCTION SWITCHER PBIO TRIGGER VALUES

The Production Switcher outputs a Peripheral Bus trigger at specific Timeline key frames, as
programmed by the operator. The 2044CL performs a specific function for each trigger value:

GRASS VALLEY GROUP Production Switcher


Trigger

Value

Mode

0

Play (If OUT point is specified, stop at OUT.)

1

Recue to beginning of clip

2

Slo-mo using ST400 Preset Speed

3

Reverse Play

4

Still Frame

5

6

Record

7 or greater

Play


SONY Production Switcher


Trigger

Value

Mode

0

Recue to beginning of clip Play

1

Play (If OUT point is specified, stop at OUT.)

2

Slo-mo using ST400 Preset Speed

3 Reverse

Play

4 Still

Frame

5
6 Record
7 or greater

Play

To control more than one VTR, enable the Peripheral Device Address for each VTR. The Trigger
value will be sent to the enabled devices.
OR

GANG the required VTRs on the ST400. See “FUNCTION TABLE,” Section 16, for GANG
instructions. Enable the Peripheral Device Address for one of the GANGed VTRs. The Trigger
will be sent to the enabled VTR. The other VTRs in the GANG will perform the same action.