Installing, Notice, Caution – Desa FPVF33PR User Manual

Page 15: Continued

Advertising
background image

15

103280

INSTALLING

Continued

Mantel Clearances for Built-In Installation

If placing mantel above built-in fireplace, you must meet minimum clearance
between mantel shelf and top of fireplace opening.

If your installation does not meet the above minimum clearances, you must:
• raise the mantel to an acceptable height, OR
• remove the mantel.

Distances to
Underside of
Mantel

Underside of
Mantel Shelf

20"

24

1/2

"

27

1/2

"

30"

All minimum
distances are
in inches

Top of
Fireplace
Opening

2

1

/2

"

6"

8"

10"

Figure 15 - Minimum Mantel Clearances for Built-In Installation

Mantel Shelf

INSTALLING GAS PIPING TO FIREPLACE LOCATION

Installation Items Needed

Before installing fireplace, make sure you have the items listed below.

• piping (check local codes)
• sealant (resistant to LP/propane gas)
• manual shutoff valve *
• test gauge connection *
• sediment trap

• tee joint
• pipe wrench
• approved flexible gas line with

gas connector

(if allowed by

local codes)

(not provided)

NOTICE

A qualified service person must connect fireplace to gas supply.
Follow all local codes.

* An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual
shutoff valve from your dealer. See Accessories, page 34.

WARNING ICON

G 001

CAUTION

Never connect heater directly to the propane supply. This heater
requires an external regulator (not supplied). Install the external
regulator between the heater and propane supply.

Continued

Advertising