Installing, Continued – Desa FPVF33PR User Manual

Page 19

Advertising
background image

19

103280

INSTALLING

Continued

Test Pressures Equal To or Less Than 1/2 PSIG

1. Close manual shutoff valve (see Figure 20).
2. Pressurize supply piping system by either using compressed air or opening main

gas valve located on or near gas meter.

3. Check all joints from gas meter to manual shutoff valve (see Figure 21). Apply

mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Fireplace Gas Connections

1. Open manual shutoff valve (see Figure 20).
2. Open main gas valve located on or near gas meter.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from manual shutoff valve to thermostat gas valve (see Figure

21). Apply mixture of liquid soap and water to gas joints. Bubbles forming
show a leak.

5. Correct all leaks at once.
6. Light fireplace (see Operating Fireplace, pages 22 and 23 [Thermostat-con-

trolled models] or pages 24 and 25 [Manually-controlled models]). Check all
other internal joints for leaks.

7. Turn off fireplace (see To Turn Off Gas to Appliance, page 23 [Thermostat-

controlled models] or page 25 [Manually-controlled models]).

Figure 20 - Manual Shutoff Valve

ON

POSITION

OFF

POSITION

Open

Closed

Manual
Shutoff
Valve

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

,,,,,,,,,,

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

QQQQQQQQQQ

Manual Shutoff Valve

Figure 21 - Checking Gas Joints

Manual Gas Valve

Propane
Supply Tank

Continued