WARNING

Turn off fireplace and let cool before cleaning.

POSSIBLE
CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Piezo ignitor nut is loose

3. Ignitor cable pinched or

wet

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode posi-

tioned wrong

REMEDY

1. Reconnect ignitor cable

2. Tighten nut holding

piezo ignitor to base
panel of log set. Nut is
located behind base
panel.

3. Free ignitor cable if

pinched by any metal or
tubing. Keep ignitor
cable dry

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace ignitor
7. Replace ignitor

OBSERVED
PROBLEM

When ignitor button
is pressed, there is no
spark at ODS/pilot

WARNING ICON

G 001

CAUTION

You must keep control areas, burners, and circulating air pas-
sageways of fireplace clean. Inspect these areas of fireplace
before each use. Have fireplace inspected yearly by a qualified
service person. Fireplace may need more frequent cleaning due to
excessive lint from carpeting, bedding material, etc.

ODS/PILOT AND BURNERS

• Use a vacuum cleaner or small, soft bristled brush to clean.

LOGS

• If you remove logs for cleaning, refer to Installing Logs, pages 20 and 21, to

properly replace logs.

• Replace log(s) if broken or chipped (dime-sized or larger).

TROUBLE-

SHOOTING

Note: All troubleshooting

items are listed in order of

operation.

WARNING ICON

G 001

WARNING

Turn off fireplace and let cool before servicing. Only a qualified
service person should service and repair fireplace.

WARNING ICON

G 001

CAUTION

Never use a wire, needle, or similar object to clean ODS/pilot. This
can damage ODS/pilot unit.