6. Continue pressing control knob in. Press and release ignitor button. This will light

pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor
button until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service person or gas supplier

for repairs. Until repairs are made, light pilot with match. To light pilot with
match, see Manual Lighting Procedure
, below.

7. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds,

release control knob.

Note:

If pilot goes out, repeat steps 3 through 7.

• If control knob does not pop out when released, contact a qualified service

person or gas supplier for repairs.

Thermocouple

Ignitor Electrode

Pilot Burner

OPERATING

FIREPLACE

Manually-Controlled

Models

Continued

8. Slightly depress and turn control knob counterclockwise

C-clockwise

to the HIGH

position. Both burners should light. Set control knob to either HIGH or LOW.

TO TURN OFF GAS TO APPLIANCE

WARNING ICON

G 001

WARNING

Do not operate heater between locked positions.

WARNING ICON

G 001

CAUTION

Do not try to adjust heating levels by using the manual shutoff valve.

VARIABLE CONTROL OPERATION

The variable control valve can be set to any heat setting and flame height desired, by
simply turning the control knob until that setting is attained. Even the lowest setting
provides realistic flames and glowing embers from two burners. Selecting higher
settings produces greater heat output. This results in increased heating comfort.

Shutting Off Fireplace

1. Turn control knob clockwise

Clockwise

to the HIGH position.

2. Slightly depress control knob and turn clockwise

Clockwise

to the PILOT position.

3. Slightly depress control knob and turn clockwise

Clockwise

to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the HIGH position.

2. Press in and turn clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Follow steps 1 through 5 under Lighting Instructions, page 24.

2. Depress control knob and light pilot with match.

3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob. Now follow step 8, above.