Installing, Notice, Warning – Desa FPVF33PR User Manual

Page 9: Caution

Advertising
background image

9

103280

INSTALLING

Continued

NOTICE

A qualified service person must install fireplace. Follow all local
codes.

WARNING ICON

G 001

WARNING

Never install the fireplace

• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable

objects are less than 36 inches from the front, top, or sides
of the fireplace

• in high traffic areas
• in windy or drafty areas

WARNING

This fireplace has a three-prong, grounded electrical plug. This
plug helps protect you against electrical shock. Only connect
plug to a properly grounded, three-prong receptacle. Do not cut
or remove the grounding prong from this plug.

WARNING ICON

G 001

CAUTION

This fireplace creates warm air currents. These currents move heat
to wall surfaces next to fireplace. Installing fireplace next to vinyl or
cloth wall coverings or operating fireplace where impurities in the
air (such as tobacco smoke) exist, may discolor walls.

IMPORTANT:

Vent-free heaters add moisture to the air. Although this is beneficial,

installing fireplace in rooms without enough ventilation air may cause mildew to
form from too much moisture. See Air for Combustion and Ventilation, pages 6
through 8.

IMPORTANT:

Make sure the fireplace is level. If fireplace is not level, log set will

not work properly.

CHECK GAS TYPE

Use only propane gas. If your gas supply is not propane gas, do not install fire-
place. Call dealer where you bought fireplace for proper type fireplace.

ELECTRICAL HOOKUP

This fireplace has a blower assembly with an electrical cord. The electrical cord is
five feet in length. You must locate fireplace within reach of a 120 volt grounded
electrical outlet. If not, you must install an electrical outlet within reach of fire-
place power cord.

Advertising