DR Power 6000-Watt Generator User Manual

Page 20

Advertising
background image

16 DR

®

GENERATOR ATTACHMENT

7. Run the Sensor Wire from the Meter to the Handlebar

(Figure 24) and secure in two (2) places as shown
with Cable Ties. Do not over tighten the Cable Ties.







8. Route the remaining Meter wire forward, following

down the existing wiring harness toward the engine
spark plug wire (Figure 25).

9. Attach the Sensor Wire to the Spark Plug Wire by

wrapping it around the plug wire as shown in Figure
25. Secure the Sensor Wire back on itself with a Cable
Tie (Figure 26). The Meter installation is now
complete.

NOTE 1: The Maintenance Meter is fully automatic with a

display that may be read at all times, whether the
engine is ON or OFF.

NOTE 2: During engine ON, the engine RPM is displayed,

when the engine is OFF, accumulated Run Time
hours is displayed.

NOTE 3: After 25 Hours of engine ON time, the meter will

automatically flash a “Change Oil” display. The
flashing will continue for several hours of operation
even after you change the oil.

NOTE 4: If the engine RPM display is not responding to

changes in engine speed, check the connections at
the Meter and Spark Plug.

Cable Ties

Figure 24

DO NOT BIND THE WIRE TOO TIGHTLY WITH THE CABLE
TIES AND AVOID PLACING THE WIRE ON OR NEAR HOT
SURFACES.

Wire routed down
existing harness to
spark plug wire.

Figure 25

Figure 26

Wrapped Sensor Wire

Spark Plug Wire

Cable Tie

Spark Plug

Advertising