Troubleshooting table (continued) – DR Power 22-Ton (July 2013 - Present) User Manual

Page 31

Advertising
background image

CONTACT US AT www.DRpower.com 31

Troubleshooting Table (Continued)

S

YMPTOM

P

OSSIBLE

C

AUSE

Leaking pump shaft seal

 Broken drive shaft; See authorized service dealer.
 Engine/pump misalignment; Correct alignment as necessary.
 Gear sections damaged; See authorized service dealer.
 Damaged shaft seal; See authorized service dealer.
 Plugged oil breather; Make certain reservoir is properly vented.

Wedge continues to
move forward when
control handle is
released

 Damaged control valve; See authorized service dealer.

Control handle does not
return to neutral when
released from forward
position

 Hydraulic fluid too cold; Warm up engine.
 Hydraulic fluid too thick; Replace hydraulic fluid.
 Hydraulic fluid contaminated; Replace hydraulic fluid.
 Damaged control valve; See authorized service dealer.

Before performing any maintenance procedure or inspection, stop the engine, wait five (5) minutes to allow all parts to cool.
Disconnect the spark plug wire, keeping it away from the spark plug.

Advertising
This manual is related to the following products: