9 Description of System Supervising SMS

In order to receive this alert SMS you should activate the function on your V24 Central & fill the phone
number where the SMS should be sent (check the V24 leaflet for more information).

Power supply supervising function

9.1


Following the type of your GSM controller, you will have the possibility to supervise the power supply with
SMS alert function. (Check if your GSM controller is equipped with a battery)
First of all your GSM module will need to be powered for minimum 24H to have the full capacity of charge.

Working description:
If the power supply is lost for 2 minutes, your GSM controller will send an alert SMS to your mobile phone.
SMS will be sent to your mobile phone when the power supply is back.

Alert SMS

Information SMS

System failures

9.2

As your GSM module has a supervising function integrated it will be able to send to you SMS status in case
of problem in your installation.

This message will be sent when BUS communication is lost between GSM module and V24 Central appear
or with the antenna if Wireless version.

This message will be sent when RF communication is lost between V24 Central and RF antenna of GSM
module.

Heart Beat SMS

9.3

If the heart beat SMS is activated on the Central V24, you will receive periodically (as defined on the V24
GSM submenu) a general status SMS to inform you about temperature of your house and activity of your
GSM controller.


WARNING !

Power supply

failure

GSM Ok!

Power is back

WARNING !

MODBUS

communication

error!

WARNING !

RF

communication

error!

My HOME

Z1 = xx°C
Z2 = xx°C
...
...
...
Z10 = xx°C

Advertising