FiberPlex VIM-MY32 User Manual

Page 11

Advertising
background image

11

 

 

 

Clock Master / Slave Switch ‐ This switch is found on the VIM‐MY32M (master) circuit board. If the VIM‐MY32 clock on the VIM‐MY32M 

is being used as the main system clock, switch this to “Master”. If the Yamaha console internal clock is being used as the master clock, set 
this switch to “Slave”.  

When using VIM‐MY cards on a fiber split, the clock selection switch on the VIM‐MY32 master card(s) must be set to “Split Position” (see above), as 
these cards will be feeding the master clock to the split console.  

NOTE: When the VIM‐MY32 is set to the “Clock Slave” position, the console must be set to use its “Internal 
48K” as the clock source. If the VIM‐MY32M is set to the “Clock Master” position or the “Split Position”, the 
console must be set to use AES Input Channel 1/2 as the clock source. 

 


Advertising