Installation requirements – Fire Magic Regal I 34 series Drop In User Manual

Page 9

Advertising
background image

REV 3 - 1407091450

L-C2-005

9

This grill is designed for outdoor use only. DO NOT use this grill
inside a building, garage, enclosed area, or under an unprotected
overhead combustible construction. See the EXHAUST REMOVAL
section on the following page for details on installing under a patio
roof. DO NOT use this grill in or on a recreational vehicle or boat.

Important: If installing this grill in a combustible surround,

the correct R.H. Peterson insulating liner must
be used.

Important: Refer to the information below to ensure all

required clearances are met.

The grill must have a minimum clearance of 18" from
combustible materials/items
AT ALL TIMES.

For the minimum clearances between the grill and any side or rear
walls, your setup must fall within one (or more) of the following:

A. Clearance between grill and strictly non-combustible wall

(i.e. brick wall, see Fig. 9-1)

• The grill must have a minimum of 4" right, left, and rear

clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)

B. Clearance between grill and a protected combustible wall

(i.e. a non-combustible wall in front of a combustible wall to
serve as a barrier. This can be accomplished by brick, or
a metal stud fi nished with non-combustible substrate, see
Fig. 9-2)

• The grill must have a minimum of 14" right, left, and rear

clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional 10"
clearance between the grill and protected wall.)

C. Clearance between grill and combustible wall

• The grill must have a minimum of 18" right, left, and rear

clearance from any combustible wall (see Fig. 9-3).

Backsplash (if applicable)

If a non-combustible backsplash exists, it must have a minimum
of a 4" clearance from the rear of the grill (to allow for proper
ventilation and prevent dangerous overheating). See Fig. 9-4.

Important: This 4" backsplash clearance must fi rst be met prior

to any non-combustible walls beginning behind it.

Fig. 9-1 Clearance 'A' Diagram

Fig. 9-2 Clearance 'B' Diagram

Fig. 9-3 Clearance 'C' Diagram

Non-combustible

Min.

4"

(Clearance required for

right, left, and rear)

Min.

14"

Non-combustible

substrate

Non-combustible 4"

Combustible

Min.

18"

(Clearance required for

right, left, and rear)

(Clearance required for

right, left, and rear)

Fig. 9-4 Backsplash clearance

Non-combustible

Backsplash

Min.

4"

Combustible

INSTALLATION REQUIREMENTS

Advertising