Fire Magic Combustible Overhead Protection Kit User Manual

Combustible overhead protection kit, For built-in gas grills only)

Advertising
background image

1

REV 0 - 1502191200

L-C2-468

INSTALLER:

Leave these instructions with consumer.

CONSUMER:

Retain for future reference.

ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746

Grill Series

Kit model #

Kit

Dimensions

Fire Magic

AOG

A530i, A430i,

C430i

24(N,P)B

36-COPK

47.5"w x 37.5"d

E660i, A660i,

A540i, C540i

30(N,P)B

42-COPK

53.5"w x 37.5"d

E790i, A790i

36(N,P)B

48-COPK

59.5"w x 37.5"d

E1060i

--

60-COPK

71.5"w x 37.5"d

If your model is not listed:

Measure your grill oven hood from left to right. Add 10”.
This calculation should be equal to or less than the
number found in the appropriate kit model.

Example: Grill width 30"+10"= 40". KIT: 42-COPK.

Table 1 - Kit models

COMBUSTIBLE OVERHEAD

PROTECTION KIT

(For built-in gas grills only)

This protection kit meets the RHP requirement when a
Fire Magic / AOG grill is installed 6' below an overhead
combustible construction.

Note: A vent hood is not required if this kit is used.

IMPORTANT INFORMATION

I n s t a l l a t i o n mu s t b e p e r fo r m e d by a q u a l i f i e d
professional service technician.

INSTALLATION REQUIRES TWO OR MORE PEOPLE.
EXERCISE EXTREME CARE DURING INSTALLATION.

Read these instructions and the safety and installation
sections of the grill owner's manual before beginning this
protection kit installation.

CLEARANCE REQUIREMENTS

Overhead construction:

Any combustible overhead contruction must be a minimum of
6 feet above the grill countertop. This clearance must include
any additional material used for mounting and/or covering
the protection kit. See Fig. 1-1 and the INSTALLATION
section of this instruction for details.

Rear wall:

The rear wall must be constructed of non-combustible
material
and must be between 4-6" from the rear of the
grill. See Fig. 1-1.

Fig. 1-1 Clearance requirements

(Echelon Diamond

grill shown)

Any combustible overhead construction must

be a minimum of 6' above the countertop.

(Countertop)

Non-combustible

rear wall

Min.

6'

Must be

between 4-6"

Continued on next page

(36-COPK protection kit shown)