FAULT SYMPTOM

P u m p o ve r h e a ts a n d s e iz e s

B e a r i n g s h ave s h o r t l i f e

P u m p vi b r a t e s o r i s n o i sy

M e c h a n i c al s e a l / G l a n d pa c k i n g h a s sh o r t l i f e

M e c h a n i c al s e a l / G l a n d le a k s e xc e s s ive l y

P u m p r e q u i re s e x c es s i ve p ow e r

P u m p l o s e s p r i m e a ft e r sta r t i n g

I n s u f f i c i e n t d i s c h a r g e pre s s u r e d e ve l o p e d

I n s u f f i c i e n t c a pa c i t y d e l i ve r e d

P u m p d o e s no t d e l i ve r l i q u i d

PROBABLE CAUSES

POSSIBLE REMEDIES

Wearing ring surfaces worn.

Replace worn wearing ring.

Impeller damaged or eroded.

Replace or call Flowserve for improved material

selection.

Leakage under sleeve due to joint failure.

Check for damage and replace joint.

Shaft sleeve worn or scored or running off center. Check and renew defective parts.

Mechanical seal /Gland packing improperly

installed.

Check alignment of faces or damaged parts and

assembly method used.

Incorrect type of mechanical seal/packing for the

given operating conditions.

Call Flowserve Service Center.

Shaft running off center because of worn bearings

or misalignment.

Check misalignment and /or for excessive bearing

wear.

Impeller out of balance resulting in vibration.

Abrasive solids in liquid pumped.

Internal misalignment of parts preventing seal ring

and seat from mating properly.

Check and call Flowserve.

Mechanical seal / Gland packing was run dry

Check mechanical seal/packing condition and source

of dry running and repair.

Internal misalignment due to improper repairs

causing impeller to rub.

Check method of assembly, possible damage or

state of cleanliness during assembly. Remedy or

Consult Flowserve, if necessary.

Excessive thrust caused by a mechanical failure

inside the pump.

Check wear condition of impeller, its clearances and

liquid passages.

Excessive grease in ball bearings.

Check method of re-greasing.

Lack of lubrication for bearings.

Check hours run since last change of lubricant, the

schedule and its basis.

Improper installation of bearings (damage during

assembly, incorrect assembly, wrong type of

bearing etc).

Check method of assembly, possible damage or

cleanliness during assembly and type of bearing

used. Consult Flowserve, if necessary.

Damaged bearings due to contamination.

Check contamination source and replace damaged

bearings.

C. Motor electrical problems

Wrong direction of rotation.

Reverse 2 phases at motor terminal box.

Motor running on 2 phases only.

Check supply and fuses.

Motor running too slow.

Check motor terminal box connections and voltage.