2 recommendations, Check axial shaft travel figure 2, Check radial shaft runout figure 3 – Flowserve SLM-6200 User Manual

Page 3: Check radial shaft deflection figure 4

Advertising
background image

3

2.4 Shaft radial runout should be less than 0.0005 mm per mm (0.0005 inch

per inch) of shaft/sleeve diameter. See Figure 3. Turn the shaft through

360° and observe the range of indicator movement.

Check Axial Shaft Travel Figure 2

0.25 mm (0.010 inch) Maximum

Acceptable Axial Movement

Maximum Acceptable Radial

Runout 0.0005 mm per mm

(0.0005 inch per inch) of shaft

diameter

Check Radial Shaft Runout Figure 3

2 Recommendations

To ensure that your SLM-6200 Mechanical Seal will provide you with the longest possible

life, we recommend the following:
2.1 New radial and thrust bearings be installed in the pump.
2.2 The saddle fits of the bearing assembly should not be worn.
2.3 The axial end float of the pump shaft must not exceed 0.25 mm (0.010 inch). See

Figure 2.

2.5 The shaft should deflect no more than 0.30 mm (0.012 inch) at the seal chamber

face. See Figure 4.

Check Radial Shaft Deflection Figure 4

Shaft should Deflect no more than

0.30 mm (0.012 inch)

Advertising