5.9 Slide the seal cartridge up to the equipment case. Insert the gland retaining bolts

through the gland holes and screw into the threaded holes on the face of the

equipment case. Tighten the retaining bolts evenly in opposing pairs. See Figure 14.

6 Completing Installation

6.1 Evenly tighten the Socket Head Cap Screws of the 2-piece split clamp collar, the Hex

Head Cap Screws of the 3-piece shrink disk collar, or the Set Screws of the 1-piece

sleeve collar to the proper torque values listed below.

Cartridge in Place (Dry Side) Figure 14

TORQUE VALUES

N-m

(ft-lbs)

Split Clamp Shrink Disk Set Screw Set Screw Penetrating

Clamp

Clamping

(Cup Point)

(Dog Point)

Fastener Alloy Steel Alloy Steel Alloy Steel Stainless Alloy

Size

Steel Steel

1/4”

14-16

5-8 9-11

(10-12)

(4-6) (7-8)

5/16” 33-35 27-30

14-16 18-20

(24-26) (20-22)

(10-12) (13-15)

3/8” 54-61 33-37

24-27 30-34

(40-45) (24-27)

(18-20) (22-25)

1/2” 122-136

68-75 54-57 81-84

(90-100) (50-55)

(40-42)

(60-62)

Advertising