Fronius Agilo 360.0-3 TL User Manual

Page 73

Advertising
background image

71

EN

Code

Description

Behaviour

Remedy

401

No communication with power
stage set possible

The inverter will automatically
attempt to connect again and,
if possible, will resume feeding
energy into the grid

If the status code is displayed
all the time: notify a Fronius-
trained service engineer

406

Power stage set temperature
sensor faulty

407

Internal temperature sensor
faulty

412

Fixed voltage mode has been
selected instead of MPP volt-
age mode, and the fixed volt-
age has been set to too low or
too high a value.

-

If this status code keeps recur-
ring, contact your system engi-
neer

415

External Emergency Stop line
is blocked

The inverter is not feeding any
energy into the grid.

Fault is rectified automatically;
If this status code keeps recur-
ring: notify a Fronius-trained
service engineer

416

No communication possible
between power stage set and
control system.

The inverter will automatically
attempt to connect again and,
if possible, will resume feeding
energy into the grid

If the status code is displayed
all the time: notify a Fronius-
trained service engineer

425

No communication possible
with the power stage set

426

Intermediate circuit charging
takes too long

Short-term interruption while
feeding energy into the grid
The inverter resumes with its
startup routine.

Fault is rectified automatically
If this status code keeps recur-
ring, contact your system engi-
neer

427

Power stage set not ready for
too long (timeout)

431

Bootloading process interrupt-
ed

The inverter is in bootloading
mode and is not feeding any
energy into the grid

Repeat the update process
If the status code is displayed
all the time: notify a Fronius-
trained service engineer

436

Receiving incorrect fault infor-
mation from the power stage
set

Short-term interruption while
feeding energy into the grid
The inverter resumes with its
startup routine.

Fault is rectified automatically
If this status code keeps recur-
ring, contact your system engi-
neer

437

General error handling started
in the power stage set

438

Receiving incorrect fault infor-
mation from the power stage
set

445

-

Compatibility error (e.g.
due to replacement of a
PC board)

-

Invalid power stage set
configuration

The inverter is not feeding any
energy into the grid for safety
reasons.

Update the inverter firmware;
If the status code is displayed
all the time: notify a Fronius-
trained service engineer

457

Grid relay sticking

The inverter is not feeding any
energy into the grid.

Notify a Fronius-trained ser-
vice engineer

459

Error when recording the
measuring signal for the insu-
lation test

460

Reference voltage source for
the digital signal processor
(DSP) is working out of toler-
ance