Technical data

*) The effective current corresponds to the specifications for conventional battery chargers

**) IMPORTANT! For indoor use only, do not expose the charger to rain or snow.

***) The output power may be reduced at higher temperatures (derating).

The proper functioning of the charger is tested at 5-85% humidity: climate class B

Acctiva Easy

1202

1204

1206

2403

6/12

12/24

Selectiva

1006

2003

/

1002/2003

Mains voltage [V AC]

100-240 V 100-240 V 100-240 V

240 V

240 V

Mains voltage tolerance

+/-15 %

+/-15 %

+/-15 %

+/-15 %

+/-15 %

+/-15 %

Grid frequency

50/60

Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

50/60 Hz

Max. open circuit power
consumption

1.5 W

1.5 W

1.5 W

1.5 W

1.5 W

1.5 W

Nominal output

18 W

36 W

48 W

48 W

18/24 W

36/43 W

Battery voltage

[V DC]

12 V

12 V

12 V

24 V

6/12 V

12/24 V

Arithmetic charging cur-
rent

[A DC]

at 230 V
at 110 V

1.5 A

0.95 A

3.0 A
1.9 A

4.0 A
2.5 A

2.0 A

1.25 A

3.0/2.0 A

3.0/1.8 A

Effective current

[Aeff. DC]

*)

2.0 A

4.0 A

6.0 A

3.0 A

4.0/3.0 A

4.0/2.5 A

Battery capacity

Acctiva

Easy

Selectiva

1-85 Ah

1-85 Ah

2-150 Ah

2-135 Ah

3-200 Ah

3-180 Ah

1.5-100 Ah

2-100 Ah

2-135 Ah

1.5-100 Ah

2-135 Ah/
1.5-90 Ah
2-100 Ah/
1.5-85 Ah

Chargeable cells

6

6

6

1/2

3/6

6/12

Duty cycle

100%

100%

100%

100%

100%

100%

Charging characteristic

IUoU

IUoU

IUoU

IUoU

IUoU

IUoU

EMC Class

EN 61000-6-3 (Class B)

EN61000-6-1

FCC 15 Class B

Protection **)

IP30

IP30

IP30

IP30

IP30

IP30

Operating temperature
***)

-20°C to 50 °C (-4°F to 122°F)

Storage temperature

-25°C to 80°C (-13°F to 176°F)

Length of time before
safety cut-out trips

Acctiva

Easy

Selectiva

75 h
75 h

75 h
75 h

56 h
75 h

75 h
75 h

29 h

44 h
75 h

Length of time to switch
off if incorrect voltage se-
lected

10 min

10 min