Ready 12 V and 24 V indicator flashing, fault indicator flashing:
Cause:
Mains fault - mains voltage outside the tolerance range
Remedy:
Check mains conditions
Ready 12 V and 24 V indicator on, fault indicator flashing:
Cause:
Short in charging circuit
Remedy:
Check charger leads, contacts and battery poles
Cause:
Charger leads connected to wrong poles
Remedy:
Connect battery poles correctly
Cause:
Connection fault
Remedy:
Check charging circuit
Fault indicator flashing (3x pattern)
Cause:
Faulty fuse when two batteries are being charged together. Where possible,
one of the two batteries will continue to be charged.
Remedy:
Replace fuse in battery, for more information on the defective fuse function
see the "Charging the battery" section.
Charging error
Fault indicator flashing, charge level indicator flashing:
Charger switches off during charging
Cause:
Battery temperature or ambient temperature too low or too high. Under-/over-
temperature protection active
Remedy:
Allow charger to cool down. Charging will recommence automatically once
the charger has cooled sufficiently. If not, have it checked by a workshop
Cause:
Timeout in the corresponding charging phase, or battery capacity too high
Remedy:
Select correct synergic line type according to the leaflet and charge again
Cause:
Battery faulty (cell short circuit, heavy sulphation)
Remedy:
Check battery and replace if necessary
WARNING! An electric shock can be fatal. Before opening the device:
-
Unplug the device from the mains
-
Disconnect battery connection
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-
Using a suitable measuring instrument, check to make sure that electrically
charged parts (e.g. capacitors) have been discharged
CAUTION! Failure to connect a correctly-dimensioned earth lead may result in
serious injury or damage. The housing screws provide a suitable PE conductor
connection for earthing (grounding) the housing and must NOT be replaced by
any other screws that do not provide a reliable PE conductor connection.