Head table operation – FSR ML-116 User Manual

Page 34

Advertising
background image

FSR

ML-116 INSTALLATION DATA

Telephone 973-785-4347

page 33

HEAD TABLE OPERATION

The head table switches on the MAP panel control relays that switch speakers located over a head

table location, on or off. When the head table switch is activated those aforementioned speakers are

disconnected whenever the microphone is in use, to eliminate audio feedback, and are connected in

all other modes of operation.

The installation of the head table controls requires the HTBC card along with the associated HT-8

cards be located in the rear of the rack housing the power amplifiers. Each HT-8 module contains

relays for eight head table locations. The ML-116 system has provisions to handle up to 32 head

table positions meaning an installation could have up to 4 HT-8 modules. All these modules come

mounted in an FSR TRAC-BRAC which facilitates rear rack mounting.

All the interconnect cables from the ML-116 ACU to the HTBC and from the HTBC to the HT-8

cards are supplied with the system.

partial view of the

HTP module

(rear of ACU)

Head Table Hookup Diagram (only one HT-8 is shown, there could be a total of 4)

from wallmount trans-

former (supplied) ML-HT

speaker line output to the speakers above the head table location in room 1

from amplifier output for room 1 in the system

RM

1

RM

2

RM

3

RM

4

RM

5

RM

6

RM

7

RM

8

HT-8 BOARD

HTBC BOARD

Advertising