Fusion MS-AV700i User Manual

Page 55

Advertising
background image

54

Internet Protocol (IP) Setting (700 Series Only)

FUSION has provided additional Ethernet network configuration options. A

Static IP address function has been added allowing installers to configure the

700 Series either for dynamic (DHCP) or Static IP address allocation.

WARNING: IF THE 700 SERIES STEREO IS CURRENLTY CONNECTED TO

AN ETHERNET NETWORK APPLYING INCORRECT IP SETTINGS MAY CAUSE

THE STEREO TO BECOME DISCONNECTED FROM THE NETWORK.

To change the IP Setting:

1. Press the Menu key.

2. Turn and then press the Encoder to select Settings > IP Address.

3. Press and turn the Rotary Encoder to select one of the following settings.

Static IP/DHCP

For Ethernet networks with a DHCP router installed select DHCP (default

setting). This function allows the network router to allocate a dynamic IP

address to the FUSION Stereo.

For installations requiring a Static IP address, select Static IP. A Static IP

screen will be displayed with the following fields;

1. Use the Forward/Rewind keys to select the IP field.

2. Turn the Encoder to display the required value.

3. Repeat Steps 1 and 2 until you have worked through all the fields you wish

to change.

4. Press and hold down the Encoder to save the changes and exit. or press

the Menu key to exit without saving the changes.

Factory Reset

The factory reset function will return all settings in the 700 Series to the

factory default value.

Warning:

All AM, FM and VHF station presents are erased. Tuner and VHF

tuner regions are reset to USA. All zones are enabled and zone settings, tone,

subwoofer filter settings, source settings and device name are returned to

default values.

To reset your 700 Series to factory default values:

1. Press the Menu Key.

2. Turn and press the Encoder to select Settings > Update.

3. Turn and press the Encoder to select Factory reset. All settings will be

restored to the factory default. At the completion of the reset process the

stereo will automatically power down and restart.

Static IP Address
IP Address
000.000.000.000

Mask
000.000.000.000

Default GW (Gateway)
000.000.000.000