Specifications, Replacement parts – GAI-Tronics 7325-106 Multi-Party Amplifier Enclosure ((ATEX Zone 2/CE Mark) User Manual

Page 6

Advertising
background image

Pub. 42004-370E

Model 7325-106 Multi-Party Amplifier Enclosure

Page

6 of 6

f:\standard ioms - current release\42004 instr. manuals\42004-370e.doc
09/13

Specifications

Construction/finish .......................................................... Sand-cast A319 aluminum alloy, cam-style latch,

hinged door with gasket; gray enamel paint

Mounting ................................................ Wall, column, or pole (mounting kit required for pole mounting),

four 0.44-inch (11.2 mm) mounting holes

Connections................................................................................ Internal screw-type barrier terminal blocks
External controls ......................................................................................................... Rotary selector switch
Dimensions ................................................... 14.50 H

 10.38 W  9.6 D inches (368.3  263.6 244 mm)

Temperature range (operating and storage) ........................................ −22º F to +158º F (−30º C to +70º C)
Shipping weight .................................................................................................................. 20.4 lbs. (9.3 kg)

Approvals

NRTL listed ..............................

...............................................................Class I, Div. 2, Groups A, B, C, D;

Class II, Div. 2, Groups F, G;

Class III, Div. 2

Class I, Zone 2, Group IIC, Class II, Zone 22

when used with listed 701-305, 701-905, 751-005 or 751-905 Amplifier

Enclosure environmental rating: Type 4X and 13

CE Mark

Replacement Parts

Contact GAI-Tronics for replacement part information.