Auxiliary output – GAI-Tronics 293-103 S.M.A.R.T. Externally Powered Emergency Phones User Manual

Page 12

Advertising
background image

PUB. 42004-377C

S.M.A.R.T.

E

XTERNALLY

P

OWERED

ADA-C

OMPLIANT

E

MERGENCY

P

HONES

P

AGE

11 of 19

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-377c.doc
08/06

Additionally, the acoustical characteristics of the emergency phones are different both when the front
panel is removed from the enclosure and when the front panel is tightly mounted in the enclosure. After
making any volume adjustments, we recommend mounting the front panel to the enclosure and again
testing the phone.

Auxiliary Output

Each telephone includes one isolated solid state output capable of switching a maximum of 48 V dc, 125
mA or 28 V

RMS

ac, 80

RMS

mA. TB2 (OUT1) on the emergency phone PCBA provides the connections for

the auxiliary output. Refer to Figure 7 for the location of TB2.

The auxiliary output allows peripheral equipment, such as beacons, video cameras, and alarm generators,
to be activated when the E

MERGENCY

push button is pressed. The relay remains energized for the

duration of the emergency call.

In many applications, the auxiliary output is used to operate a GAI-Tronics Model 530FB/531A Beacon
(sold separately). For connection details, please refer to the Model 530FB/531A installation bulletin
included with the beacon. Information is also available at www.gai-tronics.com.