Call Time-out

The call time-out feature is used to limit the maximum duration of a call. The call time-out can be any
duration between one minute and 4 ½ hours. The duration is set in ½ second increments and the valid
range is from 120 to 32,400. To determine the value associated with a specific time duration, see the
example below.

*37

Data transfer command

<120~32400> Call duration (120 to 32400 ½ seconds) – See example below.

#

End of string indicator

Example:

To determine what to enter for the call time-out duration, multiply the desired time limit, in minutes, by
120. For example, to determine the call duration entry for a call time-out of five (5) minutes, do the
following:

5 minutes

× 120 = 600

To enter a call time-out duration of five (5) minutes, enter the character string *37600#.

When the call time-out duration has been successfully entered, the phone returns a system-generated
DTMF check-digit.

Table R-1. Basic Programming Commands

Command:

Factory
Default:

Description:

*1

NN

<

CHARAC

>#

N/A

Write Memory NN (11-13) with characters (up to 24)

*37<120~32400>#

840

Write Call Time-out (120-32400

× ½ sec).

Factory default is 840, or 7 minutes.

*821

N/A

Turn on the relay output (OUT1)

*921

N/A

Turn off the relay output (OUT1)

*99

N/A

End programming call. The S.M.A.R.T. phone hangs up.