GAI-Tronics 293-101 Externally Powered ADA-Compliant Emergency Phones User Manual

Page 24

Advertising
background image

Pub. 42004-378C

E

XTERNALLY

P

OWERED

ADA-C

OMPLIANT

E

MERGENCY

P

HONES

P

AGE

23

of 28

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-378c.doc
08/06

Hardware Settings Table

Default Settings

User Settings

Function Setting

Jumper/Position

Setting

Jumper/Position

Auto-answer Enabled

J14/3

&

2

Password Protection

Enabled

J9/3 & 2

Line Polarity

Non-polarized

J6/3 & 2

Programming Table

Function Key

Sequence

Default
Settings

User Settings

Auto-dial Programming

Emergency Button Auto-dial Number 1

DD*1 *123456789*0#

Emergency Button Auto-dial Number 2

DD*2

None

Emergency Button Auto-dial Number 3

DD*3

None

Call Button Auto-dial Number

DD*4 None

Primary Dial Tone Delay

#10NN Infinite

Secondary Line Dial Tone Delay

#11NN

0 (zero) seconds

Ring-down Operation

*1

None

Password Programming

Password Protection

#14NNNN 2468

Disconnect Programming

Emergency Push-button Disconnect

#17L 01

(enabled)

Call Time-out Disconnect

#12NN 10

minutes

Dial Tone Disconnect

#19L 0

(disabled)

Other Programming Features

Silent Monitoring

#16L 0

(disabled)

Ringing #22L 0

(disabled)

ADA Programming

ADA Options Enable

#18L #181

Identification Code Entry

#13LNNN None

Table Key

D = digit 0-9, *, or #

N = digit 0-9

L = 0-Disable, 1-Enable

T = 0-350 ms, 1-50 ms, 2-25 ms