Audio, System – GAI-Tronics 10959-201 and 10959-203 Wall-mount Audio Messenger Interface User Manual

Page 10

Advertising
background image

Pub. 42004-403F

M

ODEL

10959-201

AND

-203

W

ALL

-M

OUNT

A

UDIO

M

ESSENGER

I

NTERFACES

P

AGE

8 of 20

f:\standard ioms - current release\42004 instr. manuals\42004-403f.doc
11/13

Audio

Terminal block TB3, labeled

AUDIO

is located on the termination PCBA. It provides connections for

audio inputs and outputs, and for local RS-485 data connections. Audio connections to a public address
amplifier require shielded pair conductors. Local Data connections are used with the I/O control module
and/or Zone Interface Module.

Table 4. Audio Assignment

Termination
PCBA Label

Internal
Terminal Pin-Out


Function or ACT Description

600 ohm L1

TB3-1

Page output audio to public address amplifier,
ADVANCE or Zone Interface module audio

600 ohm L2

TB3-2

AUDBUS2 L1

TB3-3

Internal audio bus and ADVANCE, ARC, or party
audio from AMI

AUDBUS2 L2

TB3-4

AUDBUS1 L1

TB3-5

Internal audio bus and ADVANCE party audio to
AMI

AUDBUS1 L2

TB3-6

PGND

TB3-7

Power supply ground

RS485 INT GND

TB3-8

RS485 INT −

TB3-9

Data/Gnd connection for I/O control module

RS485 INT +

TB3-10

System

Terminal block TB4, labeled S

YSTEM

is located on the termination PCBA. It provides connection for

system applications such system reboot, fault indicator and external data communications.

Table 5. System Assignment

Termination
PCBA Label

Internal
Terminal Pin-Out


Function or ACT Description

EXT DATA GND

TB4-1

No connection

EXT DATA-

TB4-2

Data connection for ADVANCE or external CPU
control

EXT DATA+

TB4-3

FLT

TB4-4

Active high signal representing a fault with AMI

REBOOT

TB4-5

Momentary active low signal to reboot AMI

GND

TB4-6

Ground reference for FLT and REBOOT.

AUD ACT 1

TB4-7

Isolated SSR. Closed during AMI page.
On resistance = 30 ohms

AUD ACT 2

TB4-8