Programming the Radio

1. Make sure the radio to be programmed is powered and connected to the PC (as described above)

before starting the programming software on the PC.

2. Start radio programming software on the PC.

3. Enter the receive (Rx) frequency and transmit (Tx) frequencies for each channel. To enter the

frequency, select the channel, then the Edit

button on the left.

4. Enter the Rx Frequency, Tx Frequency and select a Quiet Call (QC) frequency or Digital Quiet Call

(DQC) code, if desired.

5. After entering the frequency and optional QC or DQC, program the radio by selecting Radio >

Program Radio

from the tool bar.

6. After the radio is programmed (time bar will disappear), disconnect the programming cable and

reconnect the radio to the 69574-001 PCBA.

Attaching the Front Panel

After attaching the radio cable, place the front cover on the rear enclosure, being careful not to pinch any
cables. Secure the front cover using the four screws and washers provided. Torque the screws to 10–12
in-lbs (1.13–1.36 n-m).

Installation

Important Safety Instructions

1. Read, follow, and retain instructions – All safety and operating instructions should be read and

followed before operating the unit. Retain instructions for future reference.

2. Heed warnings – Adhere to all warnings of the unit and in the operating instructions.

3. Attachments - Attachments not recommended by the product manufacturer should not be used, as

they may cause hazards.

4. Servicing – Do not attempt to service this unit by yourself. Opening or removing covers may expose

you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.

5. This permanently connected apparatus must have a UL Listed 15-amp circuit breaker incorporated in

the electrical installation of the building.

USA and Canada Consult the National Electrical Code (NFPA 70), Canadian Standards Association
(CSA 22.1), and local codes for specific requirements regarding your installation. Class 2 circuit wiring
must be performed in accordance with NEC 725.55.

WARNING

In 24 V dc systems: Under NO condition should this equipment be operated

from a battery charger without the batteries connected.

In 24 V dc systems, most chargers have an unloaded output of 35 to 45 volts that can quickly damage the
equipment designed for nominal 24 volts. The maximum battery voltage should never exceed the
maximum specified input voltage.