P

UB

.

42004-470E

V

O

IP

C

LEAN

P

HONE

®

T

ELEPHONES

P

AGE

12 of 22

e:\standard ioms - current release\42004 instr. manuals\42004-470e.doc
02/15

Model 295-702W

The mounting and wiring instructions are as follows:

1. Remove the front panel from the back box.

2. If using Power-over-Ethernet, without any optional inputs or outputs, place the bushing around the

Ethernet cable so that it is located approximately 5 inches from the end of the cable. Snap the
bushing closed and insert into the double “D” hole in the back box. See Figure 3 and Figure 8.

3. If using local power or optional inputs or outputs, route the cables through the “D” hole in the bottom

of the back box. See Figure 3 and Figure 8.

4. Position the back box on the wall, making sure the box is level.

5. Using the back box as a template, drill holes in the lower right and upper left corners, and secure the

back box with the screws. Drill the rest of the holes you intend to use, and secure the box with the
remaining screws.

6. Plug in the Ethernet cable and connect other optional cables, as shown in the “Field Wire Installation”

section on page 14.

7. Perform the initial programming of the telephone. Refer to the “Programming” section beginning on

page 18.

8. Take the front panel of the Clean Phone

®

and align it with the four slots in the back box.

9. Press the panel in firmly, and then push downward to seat the panel in the slots.

N

OTE

: The Model 295-702W is designed for general wipe down cleaning and to prevent collection

(internally and externally) of particulate matter.

Advertising