Installation, Operation, Optional features – GAI-Tronics 751-901 SmartSeries Speaker Amplifier User Manual

Page 6

Advertising
background image

Pub. 42004-659L2F

751-901

SmartSeries

®

Speaker Amplifier

P

AGE

5 of 11

f:\standard ioms - current release\42004 instr. manuals\42004-659l2f.doc
03/12

Installation

CAUTION

Do not install this equipment in hazardous areas other than those indicated

on the approval listing in the “Specifications” section of this manual. Such installation may cause a
safety hazard and consequent injury or property damage.

The SmartSeries

®

751-901 Speaker Amplifier plugs directly into any standard GAI-Tronics 700 Series

enclosure. It also plugs into standard SmartSeries

®

enclosures such as a SmartSeries

®

station RTU

enclosure or an enclosure that houses a party line EOL Module. Use extra care not to damage the
protruding latch wings of connector J2 located on the bottom edge of the amplifier during installation.

When installing the assembly in one of these enclosures, you must also connect the 10-conductor keyed
ribbon cable to J2 on the bottom of the Speaker Amp/Power Supply PCBA. Be sure that the red line on
the edge of the cable lines up with J2-pin 1.

Ensure that the connectors mate securely and then tighten the four screws in the corners of the front panel.

Operation

The 751-901 SmartSeries

®

Speaker Amplifier amplifies incoming pages, provides speaker supervision,

and supports other optional features listed below.

Optional Features

The following features are available as options to the standard configuration of a station used in an
ADVANCE system and installed in a standard SmartSeries

®

or a custom enclosure. These features can

be configured. Contact the GAI-Tronics Field Service Department at 800-492-1212 inside the USA or
610-777-1374 outside the USA for further information about these features.

 The Selected Page Destination feature allows the manual selection of one of four page destinations.
 The Supervised Input feature allows the monitoring and supervision of one or two initiating device

circuits (IDCs), initiating an alarm when the supervised device is activated.

 The Power Relay Module provides a relay contact output, typically to switch power to a visual

signaling device, for directed or relay group operation. Supervision of the controlled device’s cable
can also be enabled.