Contact closure inputs – GAI-Tronics 12576-501(x) ADVANCE Rack-Mount Access Panel with LCD Display User Manual

Page 6

Advertising
background image

Pub. 42004-728L2D

Model 12576-501(x) ADVANCE Rack-Mount Access Panel with LCD Display

Page: 6 of 17

f:\standard ioms - current release\42004 instr. manuals\42004-728l2d.doc
08/12

Contact Closure Inputs

The DB-9 connector on the rear panel allows external switches to be
connected for access to the page switch, hookswitch and three
programmable inputs. The page and hookswitch inputs are wired in parallel
to the page switch contacts (on the handset) and hookswitch contacts (in the
handset cradle). Inputs 1–3 are wired in parallel to push buttons 26, 27 and
28 on the front panel.

Table 1. Contact Closure Input Connector - Pin Out

DB-9 Pin Number

Function

1

Input contact 1

2

Input contact 2

3

Input contact 3

4 Page

switch

5 Hookswitch

6 GND

7 GND

8 GND

9 GND

Figure 6. Typical Connection Diagram

Figure 5. DB-9 Pinout

Advertising