Lifter power connections – Hypertherm PHC Sensor User Manual
Page 39

Section 2: Installation and Setup
39
Lifter Power Connections
These connections can be made directly to a Sensor™ PHC standard lifter using the supplied cable.
Lifter Power Connections 7-Pin Circular Connector
Name
Pin #s
Signal Type
Motor power – up direction
Positive 1 Negative 2
PWM H bridge output
Lifter brake
Positive 4 Negative 5
+24Vdc output
Chassis ground
6
Motor Power
This signal is an output from the PHC. It is output from a PWM controlled “H” bridge motor drive. The
maximum current level can be set using DIP switches #1 and #2. This output is intended to drive a 24Vdc
permanent magnet motor.
Lifter Brake
This output from the PHC is a 24Vdc signal to an electromagnetic brake. When this signal is energized, the
brake is released to allow lifter motion.