Parts and kits, Recommended thc slide maintenance – Hypertherm PHC Sensor User Manual

Page 55

Advertising
background image

Section 4: Troubleshooting

55

Parts and Kits

Kit Number Description

Configured PHC Kits

228214

Sensor PHC with control module, lifter, and 50-foot cable

228242

Sensor PHC without lifter station

228243

Sensor PHC without lifter or 123895

228244

Sensor PHC without control module

228245

Sensor PHC without plasma interface

PHC Replacement Parts

228199

PHC control module assembly, complete

228200

PCB assembly, PHC processor

228201

PCB assembly, PHC motor drive

228202

Cable kit, Sensor PHC enclosure (line filter, CPC harness, wired pot)

228203

Bezel with Red Lens, for PHC control module

228204

Fuse, 1.6A Slo Blo, 1/4 x 1 1/4" (2 required)

PHC Lifter Replacement Parts

228205

Torch lifter station, 6" stroke, breakaway, PHC, complete

228206

Motor, PHC lifter (24v, w/brake, terminated)

228207

Coupling, PHC lifter

228191

Wire, ohmic contact, Ti or PHC lifter

228192

PCB assembly, Ti or PHC lifter interface

228193

Magnetic breakaway assembly, PHC/Edge Ti

228194

Breakaway Sensor/cable with fastener, terminated

228195

Ti or PHC upper sheet metal cover with fasteners

228196

Ti or PHC lower sheet metal cover with fasteners

228197

Ti or PHC lifter silicone end stop and fastener

228208

Ball screw, 2mm pitch, with nut and bearing

Recommended THC Slide Maintenance

Servicing a ball screw generally means cleaning and re-lubrication. The ball screw should be cleaned carefully
by wiping away all used grease, dust and dirt with a clean, dry cloth. If possible, move the nut several times
over the full travel to ensure that as much old grease as possible comes out of the nut. Do not use any
detergents or other cleaning fluids, such as trichloroethylene, alcohol or acetone.

NOTE: Do not remove or disassemble the ball screw or ball screw nut. After cleaning, apply a thin layer of
fresh grease over the entire surface of the screw. After re-lubrication, the assembly should be operated through
its stroke several times at low speeds and low loads to ensure that all contact surfaces of nut, balls and screw
are covered with a grease film.

Interval
Every six months

Advertising