Troubleshooting guide – Hypertherm PHC Sensor User Manual

Page 52

Advertising
background image

52

Sensor™ PHC Operation and Setup Guide

Troubleshooting Guide

Problem Solution

The Error LED and Error code
are displayed.

¾ Note the error code number and refer to the detailed list of

error indications on page 49.

No response to
CYCLE START Input

¾ Check the power switch on the PHC.
¾ Check

power

connections.

¾ Check the fuse in the power entry module.
¾ Check the cycle start connection.

Torch Ignites before IHS is
complete

¾ Check that preflow during IHS is disabled – DIP SW #12 Off.
¾ Check plasma Corner Hold Input if it is used.

No IHS motion

¾ Check that the PHC is in auto mode.
¾ Check that the torch lead set is not binding.
¾ Check that the stall force is not set too low – increase stall

force setup adjustment.

Inaccurate IHS using ohmic
contact

¾ Check that the PHC is in auto mode.
¾ Check that the ohmic contact wire is connected.
¾ Check that the torch retaining cap is tight.
¾ Check for water on the plate. If there is water present,

disconnect the ohmic wire and use stall force only.

¾ Check for oil or paint coating on the plate. If they are

present, use stall force only.

¾ Check the nozzle, shield, or both and clean or replace them.
¾ Check the work plate connection.

Inaccurate IHS using stall
force

¾ To disable ohmic sensing, disconnect the wire from the

torch tip.

¾ Check that the stall force is set correctly.
¾ Check for excessive plate deflection.
¾ Check plate support.
¾ Increase the IHS setting to compensate for plate deflection.

Torch fails to ignite

¾ Check that plasma is powered and operational.
¾ Check for proper IHS height.
¾ Check that the IHS SYNC input from the CNC is not active.
¾ Check the torch consumables.

Torch fails to Transfer

¾ Check that the pierce height is not too high.
¾ Check the work plate connection.
¾ Check the torch consumables.
¾ Check the preflow gas flow rate.