Power supply, Dimensions and weight, Powermax30 – Hypertherm Powermax30 Service Manual User Manual

Page 37: Specifications 2-2, Service manual

Advertising
background image

SPECIFICATIONS

2-2

powermax30

Service Manual

Power supply

Rated open circuit voltage (U

0

)

240 VDC

Rated output current (I

2

)

15 A to 30 A

Rated output voltage (U

2

)

83 VDC

Duty cycle at 40°C, U

1

=120 VAC

35% (I

2

= 30 A, U

2

= 83 V)

(See data plate on power supply for more

60% (I

2

=2 3 A, U

2

= 83 V)

information on duty cycle and for IEC ratings.)

100% (I

2

= 18 A, U

2

= 83 V)

Duty cycle at 40°C, U

1

=200-240 VAC

50% (I

2

= 30 A, U

2

= 83 V)

75% (I

2

= 24 A, U

2

= 83 V)

100% (I

2

= 21 A, U

2

= 83 V)

Operating temperature

14° to 104° F (-10° to 40°C)

Storage temperature

-13° to 131° F (-25° to 55°C)

Power factor (120 V — 240 V)

0.99 — 0.97

Input voltage (U

1

)/ Input current ( I

1

) at

120 V / 26 A

rated output (U

2 MAX

, I

2 MAX

)

200-240 V / 15.5-13 A

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free

99.995 % pure

Minimum required gas inlet flow and pressure

3.5 scfm @ 65 psi (99.1 l/min @ 5.5 bar)

Recommended gas inlet flow and pressure

4.0 scfm @ 80 psi (113.3 l/min @ 5.5 bar)

Dimensions and weight

Weight includes the hand torch

and 15 ft (4.57 m) lead.

20.65 lb

9.37 kg

13"

(330 mm)

5.5"

(140 mm)

10.5"

(267 mm)

11.5"

(292.1 mm)

Advertising