SPECIFICATIONS
2-2
powermax30
Service Manual
Power supply
Rated open circuit voltage (U
0
)
240 VDC
Rated output current (I
2
)
15 A to 30 A
Rated output voltage (U
2
)
83 VDC
Duty cycle at 40°C, U
1
=120 VAC
35% (I
2
= 30 A, U
2
= 83 V)
(See data plate on power supply for more
60% (I
2
=2 3 A, U
2
= 83 V)
information on duty cycle and for IEC ratings.)
100% (I
2
= 18 A, U
2
= 83 V)
Duty cycle at 40°C, U
1
=200-240 VAC
50% (I
2
= 30 A, U
2
= 83 V)
75% (I
2
= 24 A, U
2
= 83 V)
100% (I
2
= 21 A, U
2
= 83 V)
Operating temperature
14° to 104° F (-10° to 40°C)
Storage temperature
-13° to 131° F (-25° to 55°C)
Power factor (120 V — 240 V)
0.99 — 0.97
Input voltage (U
1
)/ Input current ( I
1
) at
120 V / 26 A
rated output (U
2 MAX
, I
2 MAX
)
200-240 V / 15.5-13 A
Gas type
Air
Nitrogen
Gas quality
Clean, dry, oil-free
99.995 % pure
Minimum required gas inlet flow and pressure
3.5 scfm @ 65 psi (99.1 l/min @ 5.5 bar)
Recommended gas inlet flow and pressure
4.0 scfm @ 80 psi (113.3 l/min @ 5.5 bar)
Dimensions and weight
Weight includes the hand torch
and 15 ft (4.57 m) lead.
20.65 lb
9.37 kg
13"
(330 mm)
5.5"
(140 mm)
10.5"
(267 mm)
11.5"