Initial resistance check, Powermax30 – Hypertherm Powermax30 Service Manual User Manual

Page 46

Advertising
background image

MAINTENANCE

powermax30

Service Manual

3-7

74.5 kΩ

3. Check the resistance from the input leads to ground to verify that it reads as open.

Note:

With the power disconnected and the ON/OFF switch (S1) set to OFF (O), all circuits should read
as open.
The electrical value shown is ±25%.

If no problems were found during the visual inspection or the initial resistance check, and the power supply still
does not operate correctly, see the

Troubleshooting guide.

Note:

The

Troubleshooting guide provides most probable causes and solutions. Study the system wiring

diagram and understand the theory of operation before troubleshooting. Before purchasing any major
replacement component, verify the problem with Hypertherm Technical Service or the nearest
Hypertherm repair facility.

Initial resistance check

All resistance values must be taken with the power cord disconnected and all internal power supply wires attached.
Perform the steps in

Internal inspection before continuing in this section.

• If resistance values are not close (±25%) to the values given in this section, isolate the problem by

removing wires attached to the resistance check points or component until the problem is found.

After the problem has been located and repaired, refer to the

Sequence of operation flow diagram in this

section to test the power supply for proper operation.

1. With the power disconnected, set the ON/OFF switch (S1) to ON (I).

2. Check the resistance across the input leads.

Black (CSA), brown (CE)