Sequence of operation

Power OFF

• Connect the gas supply to the air fitting on the power

supply.

• Connect the work lead to the workpiece.
• Apply power at the line-voltage disconnect box.
• Set the ON/OFF switch (S1) to ON (I)

Set the power switch (S1) to OFF (O).

• The gas solenoid valve (V1) closes.
• The gas flow stops.

• The arc extinguishes.
• Postflow continues for 20 seconds.

• Drag the torch lightly across the

workpiece to make a cut.

• The workpiece drops after the cut.
• Release the plasma start trigger on

the hand torch.

• The gas solenoid valve (V1) opens.
• The gas flow starts.
• The cutting arc starts.

• Position the torch on the workpiece.
• Pull the plasma start trigger on the torch.

The power circuits are ready.

• Set the amps adjustment knob to the desired output current

(between 15 and 30 amps) based on the input voltage and
circuit size.

• The green power ON LED illuminates, indicating the

system is ready for operation.

• All the fault LEDs should be extinguished (see

Troubleshooting guide for more information).