Test 8 — fan, Test 9 — pressure switch, Perform test 9 to verify – Hypertherm Powermax30 Service Manual User Manual

Page 60: Perform test 8 to make, Perform test 7 to test, Powermax30

Advertising
background image

MAINTENANCE

powermax30

Service Manual

3-21

Test 8 — fan

Test the fan for proper operation.

• Place a jumper from ground to pin 3 of J5. If the fan does not operate, replace the fan.

Test 9 — pressure switch

Test the pressure switch to ensure that the system is receiving the proper gas pressure.

1. Turn OFF the power.

2. Check the resistance between pins 1 and 2 of J4. It should read approximately 4.7 kΩ if there is no gas

pressure. If the gas pressure is within system tolerances, the circuit should read as closed.

J5

Ground to ground
wire clip or to the
heat sink