3-unit bridge

The preparation of the abutment teeth is the same as for anterior and posterior crowns.

Note regarding lithium disilicate glass-ceramic (LS

2

) bridges:

Given the different masticatory forces, the maximum acceptable pontic width is different in the anterior and
posterior region.

The pontic width is determined on the unprepared tooth.
– In the anterior region (up to the canine), the pontic width should not exceed 11.0 mm.
– In the premolar region (canine up to the second premolar), the pontic width should not exceed 9.0 mm.

Maximum

pontic width

9 mm

Premolar area

up to the canine

Maximum

pontic width

11 mm

Anterior region

Bridge

(4– and multi-unit bridges)

− Evenly reduce the anatomical shape while observing the stipulated minimum thicknesses.
– Prepare a circular shoulder with rounded inner edges or a chamfer at an angle of approximately

10 to 30 degrees.

− Ensure that the width of the circular shoulder/chamfer is at least 1.0 mm.
− Reduce the incisal or occlusal crown third by at least 2.0 mm.
− Reduce the vestibular and/or oral area by at least 1.5 mm.