Ips e.max, Automix – Ivoclar Vivadent IPS e.max Clinical Guide User Manual

Page 24

Advertising
background image

24

IPS e.max

®

lithium disilicate anterior crown

cemented with Multilink

®

Automix

The temporary restoration is removed. The prepara-
tion is cleaned with a polishing brush and an oil- and
fluoride-free cleaning paste (e.g. Proxyt

®

fluoride-

free). Subsequently, it is rinsed with water spray and
dried with oil-free air.

Excess Multilink Primer is dispersed with air until the
mobile liquid film is no longer visible.

Monobond

®

Plus is applied on the pretreated surface,

allowed to react for 60 seconds and then thoroughly
dispersed with air.

The permanent restoration is tried-in. For the
esthetic inspection, Multilink

®

Automix Try-In Paste

can be used.
After the try-in, the Try-In Paste is thoroughly
washed off with water spray, and the restoration is
dried with oil- and moisture-free air.

Multilink Automix is dispensed from the automix
syringe and directly applied on the restoration.

The preparation is cleaned again according to the
steps described above. Subsequently, the prepara-
tion is dried with oil-free air. Overdrying must be
avoided!

Etching is performed with 5% hydrofluoric acid
(e.g. IPS

®

Ceramic Etching Gel) for 20 seconds.

Subsequently, the preparation is rinsed thoroughly
with water and dried with oil-free air.

The restoration is seated and held in place
maintaining stable pressure.

The mixed Multilink

®

Primer A/B is applied on the

entire bonding surface (starting from the enamel
surface) using a microbrush and rubbed in for
30 seconds.

LS

2

Dr Ronny Watzke / Franz Perkon (DT), Principality of Liechtenstein