Ivoclar Vivadent SR Adoro User Manual
Page 67
Advertising

67
Apply the Liner on the entire zirconium oxide framework.
Precure the Liner with the Quick after application.
Liner
Apparatus
Time
Program
Precuring time per
segment
Quick
20 s
–
Coat all areas with a layer of SR Adoro Liner of at least
150 microns. Thin out the Liner towards the preparation
margin.
If desired, the translucency of the Liners 050–500 may be
increased by using Liner clear or Liner incisal.
Removing the inhibition layer
Thoroughly remove the corresponding inhibition layer using
a disposable sponge (do not use a solvent); make sure that
the Liner surfaces are free of residue. Make sure that the
Liner shows a mat surface.
Remove the inhibition layer with a disposable sponge.
Practical
Pr
ocedur
e
for
Fixed
ZrO
2
-Supported
Restorations