Indication
– Class I - V restorations
– Restoration of deciduous teeth
– Extended fissure sealing
– Direct veneers
– Splinting of mobile teeth
– Blocking out of undercuts
– Repair of composite and ceramic veneers
– Inlays/onlays with extraoral post-tempering

Contraindication
– if a dry working field cannot be established or the

prescribed application technique cannot be applied

– if a patient is known to be allergic to any of the

ingredients of Tetric

Side effects
In rare cases, components of Tetric may lead to sensitiza-
tion. Tetric should not be used in such cases.
To avoid possible irritation of the pulp, areas close to the
pulp should be protected with a suitable pulp/dentin pro-
tector.

Interactions
Substances containing eugenol/clove oil inhibit the poly-
merization of materials based on methacrylate. Conse-
quently, application of such materials together with Tetric
must be avoided.
Discolouration may occur in combination with cationic
mouthwashes, plaque disclosing agents and chlorhexidine.

Application
1. Shade determination

Clean the teeth prior to shade determination. The shade
is selected with the tooth still moist.

2. Establish reliable isolation, preferably with a rubber dam

(e.g. OptraDam

®

Plus).

3. Prepare the cavity according to the requirements of the

adhesive technique.

4. Clean the cavity with water spray.
5. Air dry the cavity.

6. Apply a pulp protector (calcium hydroxide) if needed;

only cover areas close to the pulp and subsequently
apply a pressure-resistant cement (e.g. Vivaglass

®

Liner).

7. Apply a matrix (e.g. OptraMatrix

®

) and an interdental

wedge, if required.

8. Apply the bonding agent according to the Instructions

for Use of the product in use. We recommend using
Syntac

®

or ExciTE

®

F (both with phosphoric acid

etching) or the AdheSE

®

One F self-etching adhesive.

9. Apply Tetric to a maximum layer thickness of 2 mm, or

1.5 mm for Dentin shade, and adapt/contour with a
suitable instrument (e.g. OptraSculpt

®

).

The OptraContact

®

instrument can be used to selectively

position high-quality proximal contacts.
Polymerize each layer according to the table below.
Hold the light emission window of the curing light as
close to the restorative as possible.

10.Finish the restoration with suitable finishers or fine

diamonds. Subsequently, check the occlusion.

11.Polish with silicone polishers

(e.g. OptraPol

®

Next Generation).

Layer

thickness

Tetric

Tetric

Light

Basic White

intensity

1.5 – 2 mm

2 mm 4 mm

500 mW/cm

2

20 s

10 s

20 s

1000 mW/cm

2

10 s

5 s

10 s

Unit

bluephase C8 bluephase bluephase 20i

Program

Turbo program

5 s

High Power

15 s

10 s

10 s

program

Soft Start

20 s

15 s

15 s

program

GI Tetric 2010_WE3_635686 Rev2_GI Tetric 2008.qxd 12.10.10 12:15 Seite 2