Ivoclar Vivadent Virtual 380 User Manual

Page 3

Advertising
background image

Contraindication
The use of Virtual impression materials is contraindicated if the patient is known to be allergic to
any of the ingredients in Virtual impression materials.
Side effects
None known to date.
Interactions
The setting of vinylpolysiloxanes is inhibited by latex gloves.
Do not touch surfaces (teeth, preparations or retraction cords, etc.) of which the impression will
be taken with latex gloves. It is recommended that operators wash their hands thoroughly or
use vinyl gloves in order to eliminate all traces of impurities. Other materials which may inhibit
the set of impression materials include rubber dam, retraction cords and retraction cord fluids. If
the operator suspects that the preparation has been contaminated, it is recommended that the
preparation be rinsed and dried to eliminate all traces of impurities.
Application
– Heavy Body (blue):
High viscosity, hydrophilic vinylpolysiloxane suitable for final impressions.

This material is recommended for use as a tray material when using the tray/wash impression
technique.

– Monophase (blue): Medium viscosity, hydrophilic vinylpolysiloxane for final impressions.

This material is recommended for use as a tray and wash material when using the dou-
ble-arch, single-phase impression technique.

– Instructions for Virtual 380 cartridge materials:

The Virtual 380 cartridge is suitable for use in conjunction with Pentamix

®

, Pentamix

®

2,

Pentamix

®

3, MixStar-eMotion, Sympress, Duomix and Domix II, PowerMix, Dynamix

Speed as well as with Modulmix mixers. Carefully remove the Virtual 380 cartridges from the
packaging.

CAUTION: Avoid dropping the heavy Virtual 380 cartridges, as this may severely damage
the cartridges, so that they can no longer be used. Pentamix, Pentamix 2, Pentamix 3,
MixStar-eMotion, Sympress, Duomix and Domix II, PowerMix, Dynamix Speed as well as
Modulmix mixers are not registered trademarks of Ivoclar Vivadent.

– Inserting the Virtual 380 cartridge:

(Please also refer to the corresponding directions for use of the manufacturer of the
mixing unit.)

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

1. Hold the cartridge with the sealed outlet openings facing upwards.
2. Grasp the flap on the sealing cap and bend it upward 90 degrees. Do not apply excessive

force in the process.

Advertising
This manual is related to the following products: