Accessories, Electrical connections – Datalogic Scanning DS6500-100-015 User Manual

Page 11

Advertising
background image

DS6500 PROFIBUS MODEL

SOFTWARE FEATURES

ENVIRONMENTAL FEATURES

Interleaved 2/5

Readable Codes

Code 39 standard

Operating
Temperature

0° to +40 °C (+32 to +104 °F)

Codabar

Code 128

Storage
Temperature

-20° to +70 °C (-4° to +158 °F)

EAN 128

Humidity

90% non condensing

Code 93 (Standard & Full ASCII) Ambient Light

EAN/UPC (including Add-on 2

Immunity

3500 lux

And Add-on 5)

Vibration Resistance 14 mm @ 2 to 10 Hz

Code Selection

IEC 68-2-6 test FC

1.5 mm @ 13 to 55 Hz

Up to 10 codes during one
reading phase

2 hours on each axis 2 g @ 70 to 200 Hz

Headers and

Shock Resistance

Terminators

Up to 128-byte headers and
128-byte terminators

IEC 68-2-27 test EA

On Line, Automatic, Test,

3 shocks on each axis

30 g; 11 ms

Operating Modes

PackTrack™

Protection Class

IP64

Config. Mode

Genius™ utility program

PHYSICAL FEATURES

Std Models

Oscill. Mirror

Dimensions mm
(inch)

110x113x99
(4.33x4.45x3.9)

113x180x104.5
(4.45x7.08x4.11)

Parameter Storage Non-volatile internal FLASH

Weight

1.5 kg (3.3 lb) 2.0 kg (4.4 lb)



Accessories:

Name Description

Part

Number

CAB-6011

Cable to C-BOX100 1 m

93A051221

CAB-6012

Cable to C-BOX100 2 m

93A051222

CAB-6015

Cable to C-BOX100 5 m

93A051223

C-BOX 100

Passive connection box

93ACC1510

INT-30

20 mA C.L. interface board for C-BOX 100

93A151022

GFC-60

90° mirror

93A201100

GFC-600

90° mirror close distance

93A201102

PWR-120

Power unit 110/230 V AC - 24 V DC

93ACC1530

BTK-6000

Terminator kit (5 pcs)

93ACC1710

PG6002

Single unit power supply – US

93ACC1718

PG6001

Single unit power supply – UK

93ACC1719

PG6000

Single unit power supply – EU

93ACC1720

FBK-6000

Fast bracket kit (2 pcs)

93ACC1721

US-60

Mounting bracket kit (5 pcs) for multisided stations

890001020

MEP-542

Photocell kit – PNP

93ACC1727

MEP-543

Photocell kit – NPN

93ACC1728

OEK-2

Optical encoder (10 m cable + spring)

93ACC1770

OEK-1

Optical encoder kit + 10 m cable

93ACC1600



Electrical Connections:


The DS6500 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and
input/output signals.

An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet),
while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the
system.

The details of the connector pins are indicated in the following table: