Datalogic Scanning DS6500-100-015 User Manual

Page 12

Advertising
background image

DS6500 PROFIBUS MODEL

26-pin D-Sub Connector Pinout

Pin Name

Function

Chassis - internally connected to GND

1 CHASSIS

Cable shield connected to chassis

20

RXAUX

Receive data of auxiliary RS232 (referred to GND)

21

TXAUX

Transmit data of auxiliary RS232 (referred to GND)

8

OUT 1+

Configurable digital output 1 – positive pin

22 OUT

1-

Configurable

digital output 1 – negative pin

11 OUT

2+

Configurable

digital output 2 – positive pin

12 OUT

2-

Configurable

digital output 2 – negative pin

16 OUT

3A

Configurable

digital

output 3 – polarity insensitive

17 OUT

3B

Configurable

digital

output 3 – polarity insensitive

18 EXT_TRIG/PS

A

External

trigger

(polarity insensitive) for PS

19 EXT_TRIG/PS

B

External

trigger

(polarity insensitive) for PS

6

IN2/ENC A

Input signal 2 (polarity insensitive) for Encoder

10

IN2/ENC B

Input signal 2 (polarity insensitive) for Encoder

14

IN3A

Input signal 3 (polarity insensitive)

15

IN4A

Input signal 4 (polarity insensitive)

24

IN_REF

Common reference of IN3 and IN4 (polarity insensitive)

9, 13

VS

Supply voltage – positive pin

23, 25, 26 GND

Supply voltage – negative pin

10

19

1

18

9

26

26-pin male D-sub Connector

Pin

RS232

RS485 Full-Duplex

RS485 Half-Duplex

20 mA C.L.

(INT-30 with C-BOX 100 only)

2 TX

TX485+ RTX485+

3 RX

RX485+

4

RTS

TX485-

RTX485-

see INT-30 instructions

5 CTS

RX485-

7 GND_ISO GND_ISO GND_ISO

* For 20 mA C.L. connections, GND is the same of the scanner power supply.


9-pin Lonworks Connector Pinout

Pin Name

Function
Cable shield internally connected

1 CHASSIS

by capacitor to chassis

9

VS

Supply voltage – positive pin

2

GND

Supply voltage – negative pin

6

VS_I/O

Supply voltage of I/O circuit

3 Ref_I/O

Reference voltage of I/O circuit

4 SYS_ENC_I/O

System

signal

5 SYS_I/O

System

signal

7

LON A

Lonworks line (polarity insensitive)

8

LON B

Lonworks line (polarity insensitive)

5

1

9

6

9-pin female Local Lonworks Connector


9-pin Profibus Connector

Pin Name

Function

1

Shield

Shield, Protective Ground resp. (optional)

2 Free

3

B-LINE (RxD/TxD-P) Received/Transmitted Data-P

4

CNTR-P

Repeater Control Signal (optional, RS485 level)

5

DGND

Data Ground (M5V)

6

+5 V

Voltage Plus (P5V)

7 Free

8

A-LINE (RxD/TxD-N) Received/Transmitted Data

9

CNTR-N

Repeater Control Signal

5

1

9

6

9-pin female Profibus Connector

(white)

10

Advertising
This manual is related to the following products: