Accessories, Electrical connections – Datalogic Scanning DS6500-100-015 User Manual

Page 21

Advertising
background image

DS6500 DEVICENET MODEL

SOFTWARE FEATURES

ENVIRONMENTAL FEATURES

Interleaved 2/5

Readable Codes

Code 39 standard

Operating
Temperature

0° to +40 °C (+32 to +104 °F)

Codabar

Code 128

Storage
Temperature

-20° to +70 °C (-4° to +158 °F)

EAN 128

Humidity

90% non condensing

Code 93 (Standard & Full ASCII) Ambient Light

EAN/UPC (including Add-on 2

Immunity

3500 lux

And Add-on 5)

Vibration Resistance 14 mm @ 2 to 10 Hz

Code Selection

IEC 68-2-6 test FC

1.5 mm @ 13 to 55 Hz

Up to 10 codes during one
reading phase

2 hours on each axis 2 g @ 70 to 200 Hz

Headers and

Shock Resistance

Terminators

Up to 128-byte headers and
128-byte terminators

IEC 68-2-27 test EA

On Line, Automatic, Test,

3 shocks on each axis

30 g; 11 ms

Operating Modes

PackTrack™

Protection Class

IP64

Config. Mode

Genius™ utility program

PHYSICAL FEATURES

Std Models

Oscill. Mirror

Dimensions mm
(inch)

110x113x99
(4.33x4.45x3.9)

113x180x104.5
(4.45x7.08x4.11)

Parameter Storage Non-volatile internal FLASH

Weight

1.5 kg (3.3 lb) 2.0 kg (4.4 lb)


Accessories:

Name Description

Part

Number

CAB-6011

Cable to C-BOX100 1 m

93A051221

CAB-6012

Cable to C-BOX100 2 m

93A051222

CAB-6015

Cable to C-BOX100 5 m

93A051223

C-BOX 100

Passive connection box

93ACC1510

INT-30

20 mA C.L. interface board for C-BOX 100

93A151022

GFC-60

90° mirror

93A201100

GFC-600

90° mirror close distance

93A201102

PWR-120

Power unit 110/230 V AC - 24 V DC

93ACC1530

BTK-6000

Terminator kit (5 pcs)

93ACC1710

PG6002

Single unit power supply – US

93ACC1718

PG6001

Single unit power supply – UK

93ACC1719

PG6000

Single unit power supply – EU

93ACC1720

FBK-6000

Fast bracket kit (2 pcs)

93ACC1721

US-60

Mounting bracket kit (5 pcs) for multisided stations

890001020

MEP-542

Photocell kit – PNP

93ACC1727

MEP-543

Photocell kit – NPN

93ACC1728

OEK-2

Optical encoder (10 m cable + spring)

93ACC1770

OEK-1

Optical encoder kit + 10 m cable

93ACC1600



Electrical Connections:


The DS6500 DeviceNet reader provides a 26-pin male D-sub connector for connection to power supply and
input/output signals.

A DeviceNet connector is used for connection to the remote Host, while a local Lonworks 9-pin female connector
connects the DeviceNet master to the first slave reader of the system.

NOTE

When using DeviceNet, the Main serial interface is disabled and must not be physically
connected.

19

Advertising
This manual is related to the following products: